ENGLISH中文

NEWS

Company News

PSC Detain Case Study 12

2024-02-23

[97]. In Jan 2024, Singapore PSCO detained MV STS SPB 1. Built in 2019, a bulk carrier.

10 items were issued 30.

1)      EPIRB survey expired.               2) SART survey expired.

3)      Fire pump malfunction, cannot provide sufficient pressure fire water.

4)      VDR survey expired.                  5) Lifeboat malfunction.

6)      Lifebuoy damaged, No equipped MOB on bridge deck.

7)      VHF survey expired.           

8)      Line throwing apparatus and smoking signal survey expired.

9)      Crew cannot under stand how to operate OWS.

10)  Sewage treatment system out of order.

[98]. MV Rubaiyat Hanif was detained in Singapore in Jan 2024, by below three 30.

1) G/E bunkering pipe separation valve (隔离阀) malfunction.

2) Pilot ladder damaged resulting the pilot dropped into sea.

3) Above three deficiencies shown SMS not proper functioned.

[99]. PSCOs observed the quick closing valve for the LSFO service tank had a device installed preventing the valve to be closed from a position outside the space.

发现低硫油燃油日用柜速闭阀安装了一套装置,该装置能够防止速闭阀从外部被关闭。


[100].
observed the LSFO service tank quick closing valve in a permanently blocked-open position. C/E could not explain to PSCOs why the blocking device was installed or how long it was in place. Upon expanding, the C/E provided the most recent Engine Room Quarterly Inspection Log on record from June 2021. Upon examination of vessels SMS procedures, PSCOs observed that a monthly checklist of the engine department should be carried out but could not find guidance on or be informed by the C/E on how to carry out the required checklists. An ISM audit of the vessel SMS is required before departure.

发现低硫油燃油日用柜速闭阀不能关闭之后,询问老轨速闭阀的这种状态持续了多久,老轨说好久没看这玩意了,不知道。随后PSCO看了船舶机舱季度检查记录薄,发现自20216月开始,速闭阀检查项目都是正常的。因此PSCO认为从检查记录和实际状况比较看,船舶没有有效的执行SMS文件,要求船舶搞一个ISM的附加审核,方能释放船舶。

BACK

Copyright©CPN Frontier (Shanghai) Co., Ltd Powered by Shbewell